| • Flow passes through outside to Inside of Disc cartridge. |
| • Uniform distribution of flow into filter housing optimize filtration process. |
| • Filter designed for Pressure rating PN8 (8 bar) / PN10 (10 bar) |
| • Disc cartridge enabled with spring loaded for full compression of disc and loosen during cleaning. |
| • Filter with Clogging indicator, Red pop up comes out at 0.6 kg/cm² pressure differential, indicates end user to clean filter manually. |
| • During cleaning operation, all inlet water passes through the pipe, and water jets removes dirt from the discs. |
• Handle for 90 degree rota on for cleaning of disc without dismantling of filter. |
Cleaning Instructions |
| • Cleaning of the filter must be done when pressure differential across the disc filter reaches 0.6 kg/cm² (8.5psi) or when the clogging indicator red button pops up. |
| • Cleaning the semi-automatic filter must be done while the filter is under pressure. |
| • Gradually open the flushing valve below the filter. |
| • To start cleaning mode of filter, turn the handle (top of the filter) 90 degree in clockwise direction. |
| • When Cleaning operation starts, system pressure might increase during cleaning operation. |
| • When cleaning operating is over, filter handle direction should be at filtration mode and then flushing valve should close gradually. |
| • In case the filter is still clogged (pressure indicator button is up). Repeat the above steps for effective disc cleaning. |